CFC-E Installation Manual
Part No. 750-459 2-3
Canada Installations (refer also to the latest edition of CAN/CSA-B149.1 and B149.2):
A vent shall not terminate:
Directly above a paved sidewalk or driveway which is located between two single family dwellings and serves
both dwellings.
Less than 7 ft. (2.13m) above a paved sidewalk or paved driveway located on public property.
Within 6 ft. (1.8m) of a mechanical air supply inlet to any building.
Above a meter/regulator assembly within 3 ft. (900mm) horizontally of the vertical center-line of the regulator.
Within 6 ft. (1.8m) if any gas service regulator vent outlet.
Less than 1 ft. (300mm) above grade level.
Within 3 ft. (1m) of a window or door which can be opened in any building, any non-mechanical air supply inlet to
any building to the combustion air inlet of any other appliance.
Underneath a veranda, porch or deck, unless:
The veranda, porch or deck is fully open on a minimum of two sides beneath the floor.
The distance between the top of the vent termination and the underside of the veranda, porch or deck is
greater than 1 ft. (30cm)
Note: For direct vent installations where the air is piped in from outside, a protective screen on the
air inlet termination elbow must be used to act as an inlet screen.
Venting Installation Tips
Where to use piping supports:
Horizontal runs - at least every five (5) feet.
Vertical runs - use braces.
Under or near elbows
Consult vent manufacturer’s recommendations for additional installation guidelines.
!
Warning
Examine the venting system at least once a year. Check all joints and
vent pipe connections for tightness, corrosion or deterioration.
!
Caution
In order to avoid personal injury or property damage:
Cut nonmetallic vent pipe with a fine-toothed hacksaw (34 teeth per inch).
Do not use nonmetallic vent pipe or fittings that are cracked or damaged.
Do not use nonmetallic vent fittings if they are cut or altered.
Do not drill holes, or use screws or rivets, in nonmetallic vent pipe or fittings.