Manual Part No. 750-263 07/2010
Model CFC
ClearFire
Condensing Boiler
Operation, Service, and Parts

Table of Contents

Questions and Answers

  • J
    Jason MaxwellAug 9, 2025
    Why does my CleaverBrooks CFC-1000 Boiler have burner can failure and high gas pressure lockouts?
    • K
      katrina59Aug 9, 2025
      If the CleaverBrooks Boiler experiences burner can failure and high gas pressure lockouts, it might be due to incorrect gas pressure. Check the regulated gas pressure to ensure it matches the specifications in Table 4-3. Also, inspect other equipment connected to the gas main to ensure the regulator and gas supply piping are appropriately sized for all appliances operating simultaneously. A dedicated, correctly sized gas pressure regulator is essential for each boiler, and the customer connection should reduce to the boiler gas train.
  • C
    creynoldsAug 16, 2025
    How to troubleshoot lightoff problems in CleaverBrooks CFC-1000 Boiler?
    • C
      Curtis FranklinAug 17, 2025
      If your CleaverBrooks Boiler is experiencing lightoff problems, several factors could be the cause. First, check the regulated gas pressure to ensure it agrees with Table 4-3, and verify that other equipment connected to the gas main has properly sized regulators and gas supply piping for all appliances operating simultaneously. You can also try increasing the fan speed in increments of 100 RPM until lightoff is successful. Other potential causes include bad cable connections, fouled or improperly spaced electrodes (which should be cleaned, replaced, and adjusted), and debris on the burner canister (clean by removing the burner can, blowing compressed air from the outside in, and vacuuming up the residue).
  • J
    Jack DrakeAug 25, 2025
    How to calibrate touch screen on CleaverBrooks CFC-1000 Boiler?
    • J
      John EdwardsAug 25, 2025
      If the touch screen on your CleaverBrooks Boiler isn't working correctly, it might be out of calibration. To fix this, go to Setup/Advanced Setup/Diagnostics from the Falcon home page. Then, under “Touch Screen,” press and follow the on-screen instructions.
  • M
    Michele Shelton MDAug 31, 2025
    Why is the display on my CleaverBrooks CFC-1000 Boiler behaving erratically?
    • H
      Heidi HallAug 31, 2025
      Erratic display or controller behavior in a CleaverBrooks Boiler can often be traced to a faulty electrical ground. Check the ground terminals in the control panel to ensure the system is firmly grounded to the metal casing. If necessary, external ground wiring may be required.

CleaverBrooks CFC-1000 Specifications

General IconGeneral
ModelCFC-1000
Operating PressureUp to 150 psi
CategoryBoiler
TypeFiretube
Fuel TypeNatural Gas