CB FALCON
3 750-265
TABLE OF CONTENTS
Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Operational Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
Communications and Displays - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8
Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9
Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Startup - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18
Pump Control - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 53
Annunciator - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 61
Fault Handling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 63
Burner Control Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 64
System Checkout - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 65
Initial Lightoff Checks - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 66
pilot Turndown Test - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 68
ignition Interference Test - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 69
Hot Refractory Hold-In Test - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 69
Ignition Spark Response Test - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 69
Safety Shutdown Tests - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 70
Troubleshooting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 71
Lead Lag - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 72
Appendix A: Parameter Glossary - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 89
Appendix B: Hydronic Device Parameter Worksheet Example - - - - - - - - - - - - - - - - - - - - 100
Appendix C: Lockout and Hold Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 105
This manual is intended to provide a general overview of the
CB Falcon hydronic and steam controls. The chosen set of
parameters for a certain boiler type needs to be functionally
tested for correct operation. Certain controllers are factory
configured for specific boiler models.
This document is a textbook version of the parameters. The
glossary beginning on page 89 provides an abbreviated
parameter explanation along with a reference page for a more
in-depth explanation.
The actual setup of the hydronic or steam control is
accomplished using the 833-3577 System Operator Interface.
Refer to manual 750-241 for the operation and setup screens.
This document will assist in understanding the parameters
being set up. The manual contains a worksheet example of
Falcon device parameters and how they might be set up to
provide a functioning system.
Note that while the worksheet shows most parameters as
being available, the actual product may have parameters made
invisible or read-only by the OEM, as applicable to specific
boiler models.
The chosen set of parameters for a certain boiler type MUST
be functionally tested for correct operation.
Access codes allow for different levels of setup:
The OEM level allows for equipment to operate within
guidelines that they feel necessary for safe and effi-
cient operation of their equipment. The OEM makes
available the parameters that the installing contractor
needs for installation adjustments of the equipment.
The installer setup information is customized by the
OEM. The access code for the installer level must be
obtained from the OEM.
The User level allows for non critical adjustments for
the individual piece of equipment. User-permitted
actions include but are not limited to:
Read the error log.
Monitor the input and output variables of the
controller.
Read parameters.
CH and DHW setpoint adjustment.