User Setup
29
Dehum with Cool Only or Hum with
Heat Only (Setup Step 37)
Depending on how AUX USE (Setup Step
32) is configured, this step is used to control
whether the equipment must be running
before the D / H output can turn on. when
Humidifying, for example, you might not want
to turn on the humidifier unless the thermostat
is calling for heat. Answering ON to this step
will mean no dehumidifying unless cool is
active or no humidifying unless heat is active.
Answering OFF to this step will allow the D /
H output to simply reflect whether the room
humidity is above the dehumidify setpoint
(AUX USE = Dehum) or below the humidify
setpoint (AUX USE = HUM).