80
CLIMATEMASTER WATER-SOURCE HEAT PUMPS
Tranquility
®
(TR) Series
Rev.: November 2, 2020
ClimateMaster Water-Source Heat Pumps
Unit Operating Conditions
Table 8: TR Series Typical Unit Operating Pressures and Temperatures
006 Full Load Cooling - without HWG active Full Load Heating - without HWG active
Entering
Water
Temp °F
Water
Flow
GPM/
ton
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp
Rise
°F
Air
Temp
Drop
°F DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp
Drop
°F
Air
Temp
Rise
°F DB
30*
1.5
2.25
3
124-134
120-130
117-127
159-179
147-167
136-156
17-22
20-25
24-29
5-10
5-10
5-10
18.7-20.7
13.6-15.6
8.5-10.5
17-23
18-24
18-24
71-81
72-82
74-84
295-315
296-316
297-317
13-18
14-19
15-20
5-10
5-10
5-10
5.9-7.9
4.2-6.2
2.5-4.5
17-23
17-23
17-23
50
1.5
2.25
3
132-142
131-141
130-140
210-230
199-219
189-209
7-12
8-13
9-14
5-10
5-10
4-9
16.2-18.2
11.9-13.9
7.7-9.7
18-24
19-25
19-25
105-115
110-120
115-125
330-350
335-355
339-359
8-13
9-14
9-14
9-14
9-14
9-14
8.2-10.2
6.1-8.1
4-6
22-28
22-28
23-29
70
1.5
2.25
3
136-146
136-146
135-145
275-295
262-282
250-270
5-10
6-11
6-11
5-10
4-9
4-9
15.1-17.1
11.1-13.1
7.2-9.2
17-23
18-24
18-24
136-146
141-151
147-157
362-382
368-388
374-394
9-14
9-14
9-14
10-15
10-15
10-15
11.3-13.3
16.9-18.9
5.6-7.6
27-33
28-34
29-35
90
1.5
2.25
3
142-152
141-151
140-150
365-385
353-373
340-360
5-10
5-10
5-10
4-9
4-9
4-9
13.8-15.8
10.2-12.2
6.6-8.6
16-22
16-22
16-22
170-180
173-183
177-187
402-422
407-427
412-432
14-19
15-20
17-22
12-17
12-17
12-17
14.4-16.4
11.1-13.1
7.7-9.1
33-39
33-39
34-40
110
1.5
2.25
3
148-158
147-157
146-156
462-482
449-469
438-458
5-10
5-10
5-10
4-9
3-8
3-8
12.5-14.5
9.2-11.2
5.9-7.9
14-20
14-20
14-20
*Based on 15% Methanol antifreeze solution
009 Full Load Cooling - without HWG active Full Load Heating - without HWG active
Entering
Water
Temp °F
Water
Flow
GPM/
ton
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp
Rise
°F
Air
Temp
Drop
°F DB
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Superheat Subcooling
Water
Temp
Drop
°F
Air
Temp
Rise
°F DB
30*
1.5
2.25
3
113-123
110-120
108-118
160-180
147-167
135-155
22-27
25-30
28-33
13-18
11-16
9-14
19.5-21.5
14.2-16.2
8.9-10.9
17-23
17-23
16-21
69-79
72-82
75-85
331-351
335-355
339-359
11-16
11-16
11-16
20-25
20-25
21-26
7.3-9.3
5.4-7.4
3.5-5.5
17-23
18-24
19-25
50
1.5
2.25
3
124-134
122-132
120-130
211-231
199-219
187-207
9-14
12-17
15-20
10-15
9-14
8-13
18-20
13.2-15.2
8.4-10.4
17-23
17-23
17-23
101-111
105-115
110-120
360-380
363-383
366-386
9-14
9-14
9-14
20-25
19-24
19-24
9.8-11.8
7.4-9.4
4.9-6.9
23-29
24-30
24-30
70
1.5
2.25
3
129-139
128-138
127-137
275-295
261-281
247-267
7-12
8-13
8-13
8-13
7-12
6-11
17.4-19.4
12.8-14.8
8.2-10.2
16-22
16-22
16-22
130-140
137-147
144-154
400-420
407-427
414-434
10-15
10-15
10-15
20-25
19-24
18-23
12.8-14.8
9.6-11.6
6.4-8.4
28-34
29-35
30-36
90
1.5
2.25
3
136-146
135-145
134-144
364-384
350-370
336-356
7-12
7-12
7-12
3-8
4-9
4-9
15.7-17.7
11.7-13.7
7.6-9.6
15-21
15-21
15-21
170-180
178-188
186-196
449-469
455-475
460-480
13-18
14-19
15-20
17-22
15-20
13-18
16-18
12-14
7.9-9.9
34-40
35-41
36-42
110
1.5
2.25
3
142-152
141-151
140-150
467-487
451-471
435-455
5-10
5-10
5-10
4-9
4-9
3-8
13.5-15.5
9.9-11.9
6.3-8.3
13-19
13-19
13-19
*Based on 15% Methanol antifreeze solution
Operating Pressure/Temperature tables include the following notes:
Airflow is at nominal (rated) conditions;
Entering air is based upon 70°F [21°C] DB in heating and 80/67°F [27/19°C] in cooling;
Subcooling is based upon head pressure at compressor service port;
Cooling air and water values can vary greatly with changes in humidity level.