NOTE:
S-2000 (for CB 2-a, CB 2-ap,
& CB 2-e ONLY)
S-1000
The Steadyburn Mode will be ON in dark or night ambient environments and OFF in
bright or daylight ambient environments. The S-1050 LED Beacon/Strobe has two
built-in photo response features: (a) dawn/dusk transition delay of 15-30 minutes and
(b) transient light acknowledgement delay of at least 3 minutes.
To activate the LEDs in the PRIMARY-STEADYBURN MODE, connect the BLACK and
RED wires to 12-24 volts AC or DC.
When in PRIMARY-STEADYBURN MODE, to change the LEDs to SECONDARY-FLASH
MODE, connect both YELLOW control wires together (i.e., CLOSED = ON).
Strobe Management Instructions
OPERATION
PHOTOCELL FEATURE (S-1050 MODEL)
DRY CONTACT
CLOSED = "ON"
RED
BLACK
YELLOW
YELLOW
(FLASH MODE)
(FLASH MODE)
DRY CONTACT
CLOSED = "ON"
COMMON (GROUND)
POSITIVE (12-24V DC or AC)
RED
BLACK
YELLOW
YELLOW
(FLASH MODE)
(FLASH MODE)
COMMON (GROUND)
POSITIVE (12-24V DC or AC)
Instructions pertain to Model S-1000 LED Beacon/Strobe, Model S-1050 LED Beacon/Strobe and Model S-2000 LED
Beacon/Strobe only.
CAUTION: REMOVE ALL POWER FROM UNIT BEFORE SERVICING.