6 OPERATORS MANUAL VITRO LINE
Services Required
Electrical Supply
VITRO – S4
Three Heater Operation
1) Supply voltage : 380V/415V, 50Hz, 3-phase, fused supply
2) Current rating : 15A each phase
Two Heater Operation
1) Supply voltage : 230V~, 50Hz, single phase, fused supply
2) Current rating : 30A
Single Heater Operation
1) Supply voltage : 230V~, 50Hz, single phase, fused supply
2) Current rating : 10A/16A (13A UK)
The fused electrical supply should terminate at an appropriate isolator located within 1m of the
beverage machine.
VITRO – S2 Instant
Single Heater Operation
1) Supply voltage : 230V~, 50-60Hz, single phase fused supply
2) Current rating : 16A (13A UK)
3) Connection to the domestic mains supply is via a factory fitted mains lead incorporating a
moulded domestic plug suitable for connection to a switched socket. The socket should be
located within 1m of the beverage machine.
6kW Model for fused 30 Amp supply.
1) as above
2) Current Rating 23A
3) The fused electrical supply must be terminated at a safety isolator switch, which provides
a contact separation of at least 3mm. The isolator should be located within 1m of the
beverage machine. Note the mains lead appropriate to the 6kW heater load is not suitable
for use with a rewireable domestic plug and no attempt should be made to fit one.
Vitro S3/X3 DUO / BEAN TO CUP / ESPRESSO
1) Supply voltage: 230V~, 50Hz, single phase fused supply
2) Current rating: 16A (13A UK)
The fused electrical supply must be terminated at a safety isolator switch, which provides a contact
separation of at least 3mm. The isolator should be located within 1m of the beverage machine.