Changing Lithium Battery on RF512 Series Transmitters
Battery Reordering
RF512, RF513 and RF516 transmitters are fitted as standard with a high power 3.6V Primary
lithium-thionyl chloride C-size cell. Manufacturers part number Saft LSH14 LIGHT. Only
replace with the same or equivalent type recommended by the manufacturer. Re-Order
number from Comark ‘RFBATT’.
Battery Change Procedure
Using a suitable screwdriver undo the two battery cover retaining screws and remove the
battery cover. Remove the exhausted battery and replace with a fresh one. Observe the
correct polarity when changing the lithium battery. Replace the battery cover and do up the
two screws taking care not to overtighten them. Observe any local restrictions on disposal of
the used cell.