DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-68
Related Programming
None
Default Settings
CO Line – CO Group = 1 for all CO Lines. (Range is 1-8.)
System Application – CO Group – Length 1 = 1 (Range is 1-4.)
System Application – CO Group – Leading 1 = 9
(Range is any available, non-conflicting Directory Number.)
System Application – CO Group – Length 2 = 3 (Range is 1-4.)
System Application – CO Group – Leading 2 = 80 (yields 800-806)
(Range is any available, non-conflicting Directory Number.)
System Application – CO Group – Length 3~5 = 3 (Range is 1-4.)
System Application – CO Group – Leading 3~5 = NULL
(Range is any available, non-conflicting Directory Number.)
Programming Abstract
Program the Lines into the CO Line Groups.
Reference Flexible Numbering Plan for programming of Directory Numbers for CO Line Groups.
Programming via the DET (Digital Extension Terminal)
Note: [back], [next], [show], [chg], [bksp], and [save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
Enter Database Administration using the feature code !+* and then enter the DB Admin password
++++++++.” (Note: This eight-character password can be changed.)
Press [show ]. The DB Item Select screen displays.
Program extensions for CO Line Access. (Index 02-ccc-03, where “ccc” = the CO Line Directory number
[740-755]):
Input 02-ccc-03 to program CO Line “ccc” – Line Group.
Press [save ]. This advances to CO Line Group for CO Line “ccc.”
Press [chg] until the appropriate CO Line Group displays for this CO Line.
Press the Volume button (up or down) to return to the DB Item Select screen and input another CO Line
Or…
Press the Hold button to select another CO Line to be programmed.
Press [show ].
Press [next ] twice to advance to the CO Line Group programming for the CO Line selected.
When finished programming CO Line Groups, press the Volume button (up or down) to return to the DB
Item Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press «.