DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-68
Related Programming
None
Default Settings
CO Line – CO Group = 1 for all CO Lines. (Range is 1-8.)
System Application – CO Group – Length 1 = 1 (Range is 1-4.)
System Application – CO Group – Leading 1 = 9
(Range is any available, non-conflicting Directory Number.)
System Application – CO Group – Length 2 = 3 (Range is 1-4.)
System Application – CO Group – Leading 2 = 80 (yields 800-806)
(Range is any available, non-conflicting Directory Number.)
System Application – CO Group – Length 3~5 = 3 (Range is 1-4.)
System Application – CO Group – Leading 3~5 = NULL
(Range is any available, non-conflicting Directory Number.)
Programming Abstract
• Program the Lines into the CO Line Groups.
• Reference Flexible Numbering Plan for programming of Directory Numbers for CO Line Groups.
Programming via the DET (Digital Extension Terminal)
Note: [back], [next], [show], [chg], [bksp], and [save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code !+* and then enter the DB Admin password
“++++++++.” (Note: This eight-character password can be changed.)
• Press [show ]. The DB Item Select screen displays.
Program extensions for CO Line Access. (Index 02-ccc-03, where “ccc” = the CO Line Directory number
[740-755]):
• Input 02-ccc-03 to program CO Line “ccc” – Line Group.
• Press [save ]. This advances to CO Line Group for CO Line “ccc.”
• Press [chg] until the appropriate CO Line Group displays for this CO Line.
• Press the Volume button (up or down) to return to the DB Item Select screen and input another CO Line
Or…
• Press the Hold button to select another CO Line to be programmed.
• Press [show ].
• Press [next ] twice to advance to the CO Line Group programming for the CO Line selected.
• When finished programming CO Line Groups, press the Volume button (up or down) to return to the DB
Item Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press «.