DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-72
Program Call Abandon Timers as required, to match CO operation. (03-41 and 03-42):
• At the DB Item Select screen input 03-41 for Talk Abandon (Call Abandon during conversation “talk” mode.)
Or…
• 03-42 for Hold Abandon (Call Abandon during on hold mode.)
• Press [chg].
• Input the value for this database item. (Accepted entries are 50-1000, in increments of 50 milliseconds.)
• Press [save ].
• To select the previous or next database item, press [back] or [next].
• When finished programming Call Abandon database items, press the Volume button (up or down) to
return to the DB Item Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press «.
Program CO Lines for Call Abandon:
• Use ¢£¤¥ to highlight “CO Line.” Then press «.
• Use ¢£¤¥ to highlight “Category 1.” Then press «. (Notice the display header “CO Line Category
1 : [1/2].” The “[1/2],” indicates that this is the first of two pages for this database programming. Page 1
shows the programmable database items for CO Line ports 1-8 (CO Lines 740-747).)
• Use the ³ and ´ buttons on the PC keyboard to select the screen of Category 1 that show the CO
Line(s) to be programmed.
• Use ¢£¤¥ to highlight Call Abandon for the appropriate CO Line. (CO Lines are listed along the left
side of the display.)
• Press « until the appropriate value displays.
• Continue programming other database items as required.
• When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• Press ° (escape) again to return to the Database Programming menu.