EasyManua.ls Logo

Comdial DX-80 - Page 129

Comdial DX-80
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-79
Program extensions for the ability to Receive (answer) CO Lines while ringing.
(01-xxx-24-cc):
Input 01-xxx-24-cc (where “xxx” = extension to be programmed and “cc” = CO Line number {01-16} to be
programmed).
Press [save ]. This advances to the Receive Assignment for the extension and specific CO Line selected.
Press [chg] until the appropriate value displays. (Y/N)
Press [back or [next] to go to the previous or advance to the next CO Line to program for this extension.
Or…
Press the Volume button (up or down) to return to the DB Item Select screen and input the next
extension/CO Line to program.
When all changes are complete, press the Volume button (up or down) to return to the DB Item Select
screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
Press any key at the program title page (as it requests) to enter the Main Menu.
Select PC-DBA from the main menu.
Select Programming from the PC-DBA menu. Then press «.
Use ¢£¤¥ to highlight “Extension.” Then press «.
Use ¢£¤¥ to highlight “Receive Assignment.” Then press «.
Use ¢£¤¥ and ³´ to highlight the extension and CO Line to change.
Press « until the appropriate data displays. (Y/N)
Use ¢£¤¥ and ³´ to highlight the next extension/CO Line to change.
Continue this process for all extensions/CO Lines to change.
When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
You will then be prompted to “Save Current Setting?”
Press “N” to abort changes and leave all data unchanged.
Press “Y” to save changes.
If you press “Y” (yes), you will then be prompted “File Exists, Override?
Press “N” to abort changes and leave all data unchanged.
Press “Y” (yes) to continue with the save operation.
Press ° (escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.