DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-79
Program extensions for the ability to Receive (answer) CO Lines while ringing.
(01-xxx-24-cc):
• Input 01-xxx-24-cc (where “xxx” = extension to be programmed and “cc” = CO Line number {01-16} to be
programmed).
• Press [save ]. This advances to the Receive Assignment for the extension and specific CO Line selected.
• Press [chg] until the appropriate value displays. (Y/N)
• Press [back or [next] to go to the previous or advance to the next CO Line to program for this extension.
Or…
• Press the Volume button (up or down) to return to the DB Item Select screen and input the next
extension/CO Line to program.
• When all changes are complete, press the Volume button (up or down) to return to the DB Item Select
screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press «.
• Use ¢£¤¥ to highlight “Extension.” Then press «.
• Use ¢£¤¥ to highlight “Receive Assignment.” Then press «.
• Use ¢£¤¥ and ³´ to highlight the extension and CO Line to change.
• Press « until the appropriate data displays. (Y/N)
• Use ¢£¤¥ and ³´ to highlight the next extension/CO Line to change.
• Continue this process for all extensions/CO Lines to change.
• When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• Press ° (escape) again to return to the Database Programming menu.
• Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this