DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-108
• Press [show ]. This advances to the DISA CO LINE (Y/N) screen.
• Press [chg] to change this data item value.
• Press [next ] to advance to DISA DAY COS.
• Press [chg] until the appropriate value displays. (This data item will determine which extension COS
model to follow for DISA calls made into the system while the system is in DAY mode.)
• Press [next ] to advance to DISA EVE COS.
• Press [chg] until the appropriate value displays. (This data item will determine which extension COS
model to follow for DISA calls made into the system while the system is in Evening mode.)
• Press [next ] to advance to SERVICE mode.
• Press [chg] until the appropriate value displays. (This data item will determine when the DISA feature
will be active for the selected CO Line. NEVER/DAY/EVE/ALWAYS.)
• Press [next ] to advance to TALK TIME.
• Press [chg] until the appropriate value for this data item displays. (The Talk Time will determine the
duration of outgoing CO Line calls made via the DISA feature on this CO Line.)
• Press [next ]. This advances to the input CO Line directory number screen so that another CO line may be
programmed for DISA if necessary.
• Input the CO Line directory number to program for DISA operation and then press [show ] and set the
necessary data item values as above.
Or…
• Press the Hold button to exit DISA programming and return to the previous menu level.
• Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press «.
• Use ¢£¤¥ to highlight “Call Handling.” Then press «.
• Use ¢£¤¥ to highlight “DISA.” Then press «.
Program Ring Time to Answer and/or Allowed Extension COS:
• Use ¢£¤¥ to highlight “DISA – Category 1.” Then press «.
• Use ¢£¤¥ to highlight the database item that requires change.
• Press « until the appropriate value displays.
• When you have completed all changes, press the ° (escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.