DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-193
Programming via the DET (Digital Extension Terminal)
Note: [back], [next], [show], [chg], [bksp], and [save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code !+* and then enter the DB Admin password
“++++++++.” (Note: This eight-character password can be changed.)
• Press [show ]. The DB Item Select screen displays.
Program extensions into Paging Groups:
• Input 01-101~156-04. Then press [save ]. This advances you to the Paging Group programming screen for
the extension selected.
• Press [chg] until the appropriate Paging Group number displays.
• Press the Volume button (up or down) to return to the DB Item Select screen.
Program External Pager to a Tenant Group and Paging Groups:
• Input 04-12-1-01. Then press [save ]. This advances to the External Pager – Tenant Group programming
screen.
• Press [chg] until the appropriate Tenant Group displays. This is the tenant group to which the external
pager will be associated.
• Press [next ] until the Paging Group to be programmed displays.
• Press [chg] until the proper setting (Y/N) displays for each of the Paging Groups. This setting determines if
the External Pager will be connected for page announcements whenever the selected Page Group is dialed.
• Press the Hold button to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press «.
Program extensions into Paging Groups:
• Use ¢£¤¥ to highlight “Extension” and then press «.
• Use ¢£¤¥ to highlight “Category 1” and then press «.
• Use ¢£¤¥ and ³´ to highlight “Paging Group” for the extension.
• Press « until the appropriate Paging Group displays for this extension.
• Continue making other programming changes as required.
• When all changes are made press the ° (escape) key to exit this database programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.