DX-80 INSTALLATION AND MAINTENANCE MANUAL
P7290 IMM 3-237
Programming via the DET (Digital Extension Terminal)
Note: [back], [next], [show], [chg], [bksp], and [save] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
• Enter Database Administration using the feature code !+* and then enter the DB Admin password
“++++++++.” (Note: This eight-character password can be changed.)
• Press [show ]. The DB Item Select screen displays. (All database programming items are indexed for fast
access. Note: Press the volume up or down bar to return to the DB Item Select screen at any time.)
• Input 03-10, then press [save ]. This advances to the Transfer-Idle Recall programming screen.
• Press [chg] until the appropriate value for this data item displays.
• Press [next ] to advance to the next data item or exit programming.
Or…
• Input 03-11, then press [save ]. This advances to the Transfer-Busy Recall programming screen.
• Press [chg] until the appropriate value for this data item displays.
• Press [next ] to advance to the next data item or exit programming.
• Press the Hold button to exit DISA programming and return to the previous menu level.
• Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
• Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«.
• Press any key at the program title page (as it requests) to enter the Main Menu.
• Select PC-DBA from the main menu.
• Select Programming from the PC-DBA menu. Then press «.
Program extensions into the tenant group:
• Use ¢£¤¥ to highlight “Call Handling” and then press «.
• Use ¢£¤¥ to highlight “Category 1” and then press «.
• Use ¢£¤¥ to highlight “XFR_I Recall” or “XFR_B Recall” as necessary for change.
• Press « until the appropriate value displays.
• When all changes are made press the ° (escape) key to exit this database programming screen. You will
see the prompt: “Exit This Feature”; press “Y” for yes.
• You will then be prompted to “Save Current Setting?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” to save changes.
• If you press “Y” (yes), you will then be prompted “File Exists, Override?”
• Press “N” to abort changes and leave all data unchanged.
• Press “Y” (yes) to continue with the save operation.
• Press ° (escape) again to return to the Database Programming menu.