Section 3: Onsite Analysis - Measurement Menu
43
The only parameter you need to set is the Fmax value. This can be
done in two ways:
¾ Press
to display the Machine Running Speed Menu
then use the number keys to enter an RPM value. The
Fmax will be set to 10 x the RPM (or rounded up to the
closest value).
OR
• Press
to display the Set Fmax Menu and use or
to select a value.
• Once the Fmax is set, select the machine, point and
direction in which the sequence of measurements will be
stored.
Recommendations
A large number of recordings will be created so we recommended
you create a new 'point' for each new coast-down or run-up
measurement to clearly separate each set of recordings.
For machines with a slow coast down or run up, e.g. more than one
minute, we recommend that you add a few seconds extra delay
between recordings (press
then enter the number of seconds
required).
The use of a tachometer is also recommended but not essential. It
obtains an RPM reading for every measurement, which aids
interpretation.
Taking a measurement
• Press
to begin the recording sequence.
• After the first spectrum has been recorded, switch off the
machine (or begin ramping its speed up or down).
• Once the machine has stopped rotating (or its speed has
been fully adjusted) press