primary address
---------------------------------------------------------------------------
1772 - Secondary 2 Short Internal and external Run Computer Setup.
Disk Port Address hard drive
Assignment controllers are both
Conflict assigned to the
secondary address
---------------------------------------------------------------------------
1780 - Disk 0 None Hard drive/format Run the
Failure error Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
1781 - Disk 1 None Hard drive/format Run the
Failure error Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
1782 - Disk None Hard drive circuitry Run the
Controller error Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
1790 - Disk 0 None Hard drive error or Run the
Failure wrong drive type Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
1791 - Disk 1 None Hard drive error or Run the
Failure wrong drive type Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
XX000Y ZZ Parity None Parity RAM failure Run the
Check 2 Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
Hard Drive 3 Long Configuration or Run the
Parameter Table or hardware failure Configuration and
BIOS Error system Diagnostics
Halted Utilities.
---------------------------------------------------------------------------
IOCHECK Active None Defective board in Run the
Slot X slot X Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
Bus Master Timeout None Defective board in Run the
Slot X slot X Configuration and
Diagnostics
Utilities.
---------------------------------------------------------------------------
Audible 1 Short Power-on successful None.
---------------------------------------------------------------------------
Audible 2 Short Power-on successful None.
---------------------------------------------------------------------------
(RESUME = F1 KEY) None As indicated Press the F1 key.
to continue
===========================================================================