XXXX - 44 Parity error
XXXX - 50 Data pins bad
XXXX - 51 Data line 7 bad
XXXX - 52 MSG, C/D and/or I/O
lines bad
XXXX - 53 BSY never went busy
XXXX - 54 BSY stayed busy
XXXX - 60 Controller CONFIG-1
register bad
XXXX - 61 Controller CONFIG-2
register bad
XXXX - 65 Media not unloaded
---------------------------------------------------------------------------
Error
Code Description Recommended Action
---------------------------------------------------------------------------
XXXX - 90 Fan failure 1. Ensure fan(s) connected.
2. Replace non-functional fan(s).
---------------------------------------------------------------------------
XXXX - 91 Over Temperature 1. Ensure proper air flow.
2. Perform required maintenance and
cleaning.
---------------------------------------------------------------------------
XXXX - 92 Side panel not N/A
installed
---------------------------------------------------------------------------
XXXX - 93 Primary redundant
power supply failed,
alternate supply
active
---------------------------------------------------------------------------
XXXX - 99 Autoloader reported 1. Install tape(s) in autoloader tape
tapes not loaded drive according to test
properly instructions.
2. Change autoloader magazine.
===========================================================================
Chapter 2.6 Troubleshooting Without Diagnostics
This section describes some simple, preliminary test and guidelines for
troubleshooting the computer without using the diagnostics.
Checklist for Solving Minor Problems
If you encounter some minor problem with the computer or software
application, review the following checklist for possible solutions before
running any of the diagnostic utilities: