14. TECHNICAL DATA
Trademark:
COMPUTHERM
Model identier: E400RF
Temperature control class: Class I
Contribution to the e󰀩ciency of seasonal space heating: 1 %
Temperature measuring range 0 °C – 50 °C (in 0.1 °C increments)
Temperature measurement accuracy ±0,5 °C
Adjustable measuring range: 5 °C – 99 °C (in 0.5 °C increments)
Switch sensitivity: ±0.1 °C - ±1.0 °C (in 0.1 °C increments)
Temperature calibration range: ±5 °C (in 0.1 °C increments)
Supply voltage: USB-C 5 V DC, 1 A
Operating frequency: RF 433 MHz, Wi-Fi (b/g/n) 2.4 GHz
Transmission distance: approx. 250 m in open terrain
Storage temperature: -5 °C … +55 °C
Operating relative humidity: 5 % - 95 % without condensation
Protection against environmental impacts: IP30
Standby power consumption: Max. 0.1 W
Dimensions: 130 x 23 x 92 mm with the holder (W x H x D)
Weight: 156 g thermostat + 123 g holder
Type of the temperature sensor: NTC 3950 K 10 kΩ 25 °C