3029-0154B Section 14: Troubleshooting
Concordia Integra Technical Support Manual 14-53
2900-255B
Flavor System – No Flavor in Drink– PAGE 2
One syrup/
sauce failed to
pour?
Yes
Pump
tubing
leaking?
No
Debris in
tubing to
door?
Pump
activates?
No No
Swap power lead
from different
syrup pump and
activate.
No
Yes
Inspect tubing in
pump for
deformity.
Pump
activates?
Yes
No
Replace pump
assembly.
PN 2345-002
Syrup driver
failure replace
and retest.
Pump
tubing
OK?
Repair leak, clean debris
from tubing, or replace
tubing and fittings as
needed. Retest for syrup.
Yes
Syrup/sauce
pours?
YesYes
Yes
Replace tubing.
PN 98590
No
Retest for syrup
pouring
properly.
Inspect tubing in
bin door and syrup
manifold for
blockage.
No
END PROCESS
Chocolate
valve
failed?
Yes
Verify voltage to
valve, clean
debris, replace
plunger or valve as
needed.
PN 1210-017
Verify syrup
timings are
appropriate.
No
Door/manifold
blockage?
Replace manifold
as needed.
PN 2790-130
Replace tubing as
needed.
Yes
No
Syrup/sauce
pours?
Yes
No
Call Concordia
Coffee Systems
for assistance.
1-800-778-0990

Table of Contents

Other manuals for Concordia Integra

Related product manuals