Edition 05/2021 - MC – Technical documentation - page 33
SACOME, CONFIDENTIAL Document, it is forbidden to duplicate or communicate this document without previous authorization.
10.8.3 Diagnostics
The menu allows supplying and testing separately all the outlets:
Press to activate the outlet
Press to disable the outlet
Diagnostic
Output
On / Off
Next step
Steam 1: XXX °C (Real temperature read in the steam boiler)
Steam 2: XXX °C (Real temperature read in the steam boiler)
Steam 3: XXX °C (Real temperature read in the steam boiler)
Coffee 1: YY °C (Real temperature read in the 1° coffee boiler)
Coffee 2: YY °C (Real temperature read in the 2° coffee boiler)
Coffee 3: YY °C (Real temperature read in the 3° coffee boiler)
R grp 1: ZZ °C (Real temperature read in the 1° head group)
R grp 2: ZZ °C (Real temperature read in the 2° head group)
R grp 3: ZZ °C (Real temperature read in the 3° head group)
Pump: Pump motor
Filling up valve: Filling up valve for steam boiler
Coffee 1 valve: Coffee valve for group n° 1
Coffee 2 valve: Coffee valve for group n° 2
Coffee 3 valve: Coffee valve for group n° 3
Pre-Inf valve Grp 1: Pre-Brewing valve for group n° 1
Pre-Inf valve Grp 2: Pre-Brewing valve for group n° 2
Pre-Inf valve Grp 3: Pre-Brewing valve for group n° 3
Hot water 1 valve: Left hot water valve + Left cold water valve
Hot water 2 valve: Right hot water valve + Right cold water valve
Steam C. Valve: Steam valve for steam control
Vacuum valve grp 1:
Vacuum valve grp 2:
Vacuum valve grp 3:
Air valve: Air valve for steam control
On / Off: Relay dedicated to supply the light transformer
For the next Outlets
:
Output
On / Off