12 QUALITY CRITERIA
Quality criteria programming:
First, the user may choose his own quality criteria.
These are the acceptable minimum and maximum flow rates for the estimated product.
The user needs to choose the type of display « Quality criteria »:
The display during the extraction becomes:
The cursor moves (7 positions) depending of the measured flow (ml/s).
There are minimum and maximum values for espresso.
There are minimum and maximum values for coffee.
The cursor shows 7 positions matching to 7 values included between the programmed
mini and max.
For example: programmed value: Min = 0.80 ml/s / Max = 1,20 ml/s
Position 1 = flow between 0.80 ml/s and 0.86 ml/s
Position 2 = flow between 0.86 ml/s and 0.91 ml/s
Position 3 = flow between 0.91 ml/s and 0.97 ml/s
Position 4 = flow between 0,97 ml/s and 1,02 ml/s (median position)
Position 5 = flow between 1,02 ml/s and 1,08 ml/s
Position 6 = flow between 1,08 ml/s and 1,14 ml/s
Position 7 = flow between 1,14 ml/s and 1,20 ml/s
- - - - - -
Quality Criteria
«
-
+
√
√
ESP Value (ml/s)
Min:1.5 Max:2.2
-
+
√
KF VALUE (ml/s)
Min:2.5 Max:4.5
-
+
√
+ or – to change the value
√ to validate and proceed
Adjustable value: 0,5 to 4,5
The mini can’t be > to the maxi
+ or – to change the value
√ to validate and proceed
Adjustable value: 0,5 to 6
The mini can’t be > to the maxi