EasyManua.ls Logo

Conti Monaco MC - Page 47

Conti Monaco MC
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Edition 05/2021 - MC – Technical documentation - page 47
SACOME, CONFIDENTIAL Document, it is forbidden to duplicate or communicate this document without previous authorization.
ANNUAL MAINTENANCE:
A kit n° 450201, for the following operation is available for sale.
Change the pump inlet filter (No. 411861)
On the steam boiler:
o Change vaccum valve (No. 408898)
o Change the safety valve (No. 411827)
On the coffee boiler:
o Remove and clean the gasket limiter 12 Bars (1,2 MPa)
o Clean the draining valve core
On the inlet bloc valves:
o Change the filter (No. 470199)
o Replace the gasket (No. 219000) of 2 non-return valves
o Remove and clean the gasket limiter 12 Bars (1,2 MPa)
o Clean the nucleus of the solenoid inlet water boiler
On the cold water valve block:
o Clean the both cold water valves cores
On the pre-brewing valve:
o Clean the pre-brewing valve core
On the coffee groups
o Change the O-ring nozzle (No. 403457) and the filter nozzle (No. 403458)
o Clean the 3rd way and the nucleus of the solenoid coffee valve
On the 2 electrical taps
o Clean the nucleus of the solenoid "hot water" valve
On the 2 steam taps:
o Change the 2 O-rings (No. 403457)
o Change the 1 gasket (No. 407502)
On the 2 "steam" output and on the 2 "hot water" output
o Change the O-ring (No. 061200)
o Change the O-ring (No. 055300)
For water quality issues, it is recommended to fully drain the boiler.