135
User Defined Motors
5. Confirm that the motor velocity is really 6 RPM by confirming that it takes 10 seconds to make one revolution. If this is
not the case, the problem may be that both the motor poles and the encoder line density are off by the same factor.
6. Reduce the analog command voltage to zero volts and disable the drive.

Table of Contents