19
Setting Up Parameters
Torque Level 1 and 2
This parameter sets the activation level for the Torque Level 1 Active and Torque Level 2 Active output functions.
Peak Torque Available
This displays the maximum torque available from the selected drive and motor combination. This is calculated by
PowerTools Pro and is not a drive parameter.
Online Tab
Torque Group
Torque Command
The torque available from the particular drive and motor combination.
This parameter returns the torque command value before it is limited. The torque command may be limited by either the
Torque Limit (if the Torque Limit Enable input function is active) or Current Foldback.
Torque Cmd Limited
This displays the percent of torque being commanded to the motor. This value is the result of the Torque Command after
being limited by the current foldback and the Torque Limit value (if active).
Foldback RMS
This parameter accurately models the thermal heating and cooling of the drive and motor. When it reaches 100 percent,
current foldback will be activated.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques Epsilon EP-I and is the answer not in the manual?

Control Techniques Epsilon EP-I Specifications

General IconGeneral
BrandControl Techniques
ModelEpsilon EP-I
CategoryControl Unit
LanguageEnglish

Related product manuals