4.5.6 10301 – 10333 Measurement Table
The measurement table provides 25 readable values as listed in the following table. The table values are
updated every 100ms.
Address Purpose Type
10301 Motor Torque Integer
10302 Motor Power Integer
10303 Motor Speed Integer
10304 Freq Out Integer
10305 Freq Ref Integer
10306 REMOTE Indication Unsigned short
10307 Motor Control Mode Unsigned short
10308 Active Fault Unsigned short
10309 Motor Current Unsigned integer
10310 Motor Voltage Unsigned integer
10311 Freq Min Unsigned integer
10312 Freq Scale Unsigned integer
10313 DC Voltage Unsigned integer
10314 Motor Nom Current Unsigned integer
10315 Motor Nom Voltage Unsigned integer
10316 Motor Nom Freq Unsigned integer
10317 Motor Nom Speed Unsigned integer
10318 Current Scale Unsigned integer
10319 Motor Current Limit Unsigned integer
10320 Deceleration Time Unsigned integer
10321 Acceleration Time Unsigned integer
10322 Freq Max Unsigned integer
10323 Pole Pair Number Unsigned integer
10324 Ramp Time Scale Unsigned integer
10325 Ms Counter Unsigned integer
Table 4-16: Measurement Table
4.6 Input Registers (3x)
The Input Registers include read only data. See below for a more specific description of the registers.
4.6.1 Operation Day Counter 30001 – 30007
Address Purpose
30001 Years
30002 Days
30003 Hours
30004 Minutes
30005 Seconds
Table 4-17: Operation Day Counter
4.6.2 Reset table Operation Day Counter 30101 – 30107
Address Purpose
30101 Years
30102 Days
30103 Hours
30104 Minutes
30105 Seconds