Service Handbook OEB/OES/OGB/OGS
AS/11-2011 2_03_01e_Standby mode_b
Notice:
The control loop of the cooking programme has priority over the standby mode
of the steam generator. This means, for example, that the convection
programme selected temperature will be attained first, before the steam
generator standby mode temperature is attained.
When the water level falls below the longer level probe (B1 - rd) 2 within a
short time an error code is triggered.
The steam generator temperature is regulated by the preheating probe B4 3.
Only after the oven has reached the standby mode temperature, will the timer
begin running in programmes with steam.
A safety thermostat monitors the maximum temperature of the heaters and
burners.
Cross reference:
Service Handbook 6.7 Assembly of the Steam generator and Immersion
heating element.
Service Handbook 6.6 Water Level Probe
Service Handbook 5. Trouble shooting and Error Codes Electronic
2.3.1b Standby mode for units with direct injection
Page 2 / 2
Notice:
Units with direct injection are in standby mode directly after being switched on.