Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 10 / 21
easy
touch
OEB OES OGB OGS
Error
message
Error description
Possible cause or remedy
E81.0 Programme memory
error
If the working parameters of a multi-step
programme are not between min. and max. values
After saving a cooking plan in the cookbook the
temperature display is changed from °C to
°Fahrenheit
E82.0 WP error
(working parameter
error)
If the working parameters of a cooking programme
are not between min. and max. values
Invalid data stored in the cookbook
E83.0 Alg. error (invalid
cooking algorithm)
Incompatible software between operating module
and control module
E83.0
ID=47
Invalid cooking
algorithm
The cooking programme is not recognised
Old software version
Wrong entry in the recipe data bank
E89.0 External memory
module defective
The external memory module (IDM module) in the
cable harness is defective
Contact problems of the X10 plug
E89.1
ID=48
Data in IDM module
not valid
IDM defective
Checksum faulty Disconnect appliance from
mains for 10 secs. and restart
E95.0 Software error
Communication problems between software and
hardware
Different hardware and software versions which
cannot work together
E96.0
ID=30
Communication
error
Connection faulty
between control
module and
operating module
Interface cable between control module and
operating module interrupted
Plug on the control module or operating module
loose
Communication between CM and OM disturbed
briefly Disconnect appliance from mains for
10 secs. and re-start
Wrong software on the control module (for et)
Control module defective (for et)
E99.0 Communication
interface to CM was
unable to be opened
Initialisation error for COM interface Disconnect
appliance from mains for 10 secs. and re-start
E99.9
ID=32
General initialisation
error
Disconnect appliance from mains for 10 secs. and
restart
Not
enough
cleaner
pressur
e
Too little flow
pressure on the
pressure switch S2
(after 40 secs. still
below 0.1 bar)
Cleaner level/nozzle flushing agent level in the
canister too low
Piping in the pump box is kinked
Suction hose not in the cleaner fluid / nozzle
flushing agent

Table of Contents