EasyManua.ls Logo

Convotherm OEB Series - Page 237

Convotherm OEB Series
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 21 / 21
OEB OES OGB OGS Error
message
Error description
Possible cause or remedy
E03.0-
0-0
Fan malfunction
(excessive
temperature in the
motor winding)
thermoprotection
contact has tripped
Fan motor has excessive temperature in the winding
a) One phase is missing from the power connection
b) Fan motor is defective
c) One phase is not connected through from the
contactor
d) Microfuse F10 (6.3 A or 10 A for floor models)
has tripped
e) Thermoprotection contact in the motor winding
(bi-metallic strip) defective or interrupted
E03.0-
0-0
CrF
Charging switch
(ALTIVAR [41] display)
Replace the converter
E03.0-
0-0
InF
Internal fault
(ALTIVAR [41] display)
Check the environment (electro magnetic
compatibility)
Replace the converter
E03.0-
0-0
ObF
Excess voltage at
end of process
(ALTIVAR [41] display)
Braking or driving load too strong
E03.0-
0-0
OCF
Excess current
(ALTIVAR [41] display)
Moment of inertia too high or load too strong.
Check the motor /converter dimensioning / check
load
Mechanical blockage, check the mechanics
E03.0-
0-0
OHF
Converter
overloaded
(ALTIVAR [41] display)
Check the motor load, converter and environment
ventilation. Wait for it to cool down before switching
on again.
E03.0-
0-0
OLC
Excess current
(ALTIVAR [41] display)
Current strength above overload threshold value
Check mechanics (wear and tear, mechanical
steering heaviness, lubrication, obstructions,…)
E03.0-
0-0
OLF
Motor overload
(ALTIVAR [41] display)
Check the thermoprotection settings for the motor
and motor overload. Wait for it to cool down before
switching on again.
E03.0-
0-0
OSF
Excess voltage
(ALTIVAR [41] display)
Check the mains voltage
E03.0-
0-0
SCF
Motor short circuit,
insulation fault
(ALTIVAR [41] display)
Check connection cable between converter and
motor and the motor insulation
E03.0-
0-0
USF
Under voltage
(ALTIVAR [41] display)
Check the mains voltage

Table of Contents

Related product manuals