Mini-world service manual
KD / 31.03.2009 5_00d_Fehlersuchliste_Mini_f_EN.doc
Page 4 / 9
Error
message
Error description
Possible cause or remedy
ST
5020
ST
7000
easy
touch
E29.1
ID=15
CTS1 short
circuit to earth
• Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.2
ID=16
CTS2 short
circuit to earth
• Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.3
ID=17
CTS3 short
circuit to earth
• Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.4
ID=18
CTS4 short
circuit to earth
• Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E81.0 Programme
memory error
• If the working parameters of a multi-step programme are not
between min. and max. values
• After saving a cooking plan in the cookbook the temperature
display is changed from °C to °Fahrenheit
E83.0 Alg. error (invalid
cooking
algorithm)
• Incompatible software between operating module and control
module
E83.0
ID=47
Invalid cooking
algorithm
• The cooking programme is not recognised
• old software version
• wrong entry in the recipe data bank
E89.1
ID=48
Data in IDM
module not valid
• IDM defective
• Checksum faulty Disconnect appliance from mains for 10
secs. and restart
E96.0
ID=30
Communication
error
Connection faulty
between control
module and
operating module
• Interface cable between control module and operating module
interrupted
• Plug on the control module or operating module loose
• Communication between CM and OM disturbed briefly
Disconnect appliance from mains for 10 secs. and re-start
• Wrong software on the control module (for et)
• Control module defective (for et)