Mini-world service manual
KD / 31.03.2009 5_00d_Fehlersuchliste_Mini_f_EN.doc
Page 4 / 9
Error
message
Error description
Possible cause or remedy
ST
5020
ST
7000
easy
touch
E29.1
ID=15
CTS1 short
circuit to earth
Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.2
ID=16
CTS2 short
circuit to earth
Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.3
ID=17
CTS3 short
circuit to earth
Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.4
ID=18
CTS4 short
circuit to earth
Thermoelement sensor B10 has contact with appliance
housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E81.0 Programme
memory error
If the working parameters of a multi-step programme are not
between min. and max. values
After saving a cooking plan in the cookbook the temperature
display is changed from °C to °Fahrenheit
E83.0 Alg. error (invalid
cooking
algorithm)
Incompatible software between operating module and control
module
E83.0
ID=47
Invalid cooking
algorithm
The cooking programme is not recognised
old software version
wrong entry in the recipe data bank
E89.1
ID=48
Data in IDM
module not valid
IDM defective
Checksum faulty Disconnect appliance from mains for 10
secs. and restart
E96.0
ID=30
Communication
error
Connection faulty
between control
module and
operating module
Interface cable between control module and operating module
interrupted
Plug on the control module or operating module loose
Communication between CM and OM disturbed briefly
Disconnect appliance from mains for 10 secs. and re-start
Wrong software on the control module (for et)
Control module defective (for et)