Mini-world service manual
KD / 31.03.2009 5_00d_Fehlersuchliste_Mini_f_EN.doc
Page 6 / 9
IDM
error
IDM module error
• When switching on and booting the appliance controller finds no
viable record in the IDM. If there is a viable record in the CM itself,
there is an attempt to transfer this to the IDM. If this works, the
error disappears, if not, the error always appears briefly when
switching on
Fit new IDM
Defect
Possible cause or remedy
5.2 General
5.2.1 No interior lighting, however
appliance fully functioning
• Light bulb of interior light defective
• Microfuse defective
5.2.2 After starting a programme
appliance not functioning
• Doors not closed
• Magnet on the door is not in the right position
• Solenoid switch defective
• Appliance is set to dummy version Set to normal
version: c12=305; c13=999
5.2.4 Water runs underneath the floor of
the appliance from the condenser
overflow
• Building’s drainage pipe blocked
• Building’s tundish funnel blocked
5.2.5 Water inside the oven
• Dirt filter in the outflow of the working chamber
contaminated
• Condenser blocked (dirt filter not present)
5.2.6 No temperature increase in
convection mode
• Safety temperature limiter B7 has tripped
• Heater contactors do not pull in
a) Contact problem on heater terminals
b) Heater contactor defective
• Hot air heaters defective
5.2.7 Uneven browning
• Suction plate not correctly fitted
• Heat produced by the hot air heater is too low
• Application error: e. g. not sufficiently pre-heated
• Load not centrally placed in the oven
5.2.8 Water drips out of the front area of
the appliance floor in table-top models
• Seal between inner and outer housing is worn or
missing
• Outflow blocked
• Door seal worn
5.2.9 Too dry or too wet in programmes
with steam
• Solenoid valves are not closing properly
• Demoisturisation activated