Service manual OEB/OES/OGB/OGS
KD / 19.08.2009 5_00e_Troubleshooting list and error messages - Electronics_h.doc
Page 7 / 21
easy
touch
OEB
OES
OGB
OGS
Error
message
Error description Possible cause or remedy
ID=20
Excessive
temperature (if
temperature
measured in the SG
>120°C)
agents)
Calcification of the steam generator
Boiling dry of the immersion heaters due to double
level sensor's short circuit to earth
E15.0
ID=21
Condenser sensor
(B3- thermoelement)
excessive
temperature
(if temperature in
the condenser
measured > 110°C)
Water reservoir in the condenser too hot:
a) Tap closed
b) Appliance connected to hot water
c) Solenoid valve “condenser cooling” defective
d) Coil from the solenoid “condenser cooling”
defective
e) Inlet filter in the solenoid valve contaminated
f) Quenching nozzle in the condenser/siphon blocked
E21.0
ID=5
Oven sensor (B6-
thermoelement)
interruption
Sensor wiring interrupted (plug X16 of the control
module)
Oven sensor (B6) interrupted (defective)
E21.1
ID=14
Oven sensor B6 (in
front of fan) - Short
circuit to earth
Thermoelement sensor (B6) has contact with
appliance housing
Thermoelement (B6) defective
E22.0 Core temperature
sensor
(B10- thermoelement)
interruption (if more
than 2 measuring
points are interrupted)
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (defective)
E22.1
ID=6
CTS1 core
temperature sensor
failure
(B10- thermoelement)
interruption
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (more than 2
thermoelements
defective)
E22.2
ID=7
CTS2 core
temperature sensor
failure
(B10- thermoelement)
interruption
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (more than 2
thermoelements
defective)
E22.3
ID=8
CTS3 core
temperature sensor
failure
(B10- thermoelement)
interruption
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (more than 2
thermoelements
defective)
E22.4
ID=9
CTS4 core
temperature sensor
failure
(B10- thermoelement)
interruption
Sensor wiring interrupted (plug X16 of the control
module)
CTS sensor (B10) interrupted (more than 2
thermoelements
defective)
E23.0 Steam generator (B4
thermoelement)
Sensor wiring interrupted (plug X16 of the control
module)