Mini-world service manual
KD / 31.03.2009 6_01d_Steuerelektronik demontieren und montieren_Mini_b_EN.doc
Page 7 / 8
disconnect the two 12 V output
cables (from the Wago terminals).
If a new SM with metal housing has
already been fitted, disconnect all of
the cables from the supply module.
If using an old supply module
unscrew the 4 knurled nuts on the
supply module and remove the
supply module from the fixing pins
evenly and in a straight line.
Remove the spacers.
If using a new supply module
remove the two hexagon nuts on the
reverse side of the vertical bearing
plate and
pull off the entire housing.
Instructions: Assembling supply module
If an old supply module was present,
first fit the retaining bracket from
your supply module retrofit kit item
no. 2619973.
Reconnect the cables to the
terminals of the supply module in
accordance with the accompanying
instructions.
Re-assemble the entire housing of
the supply module.
Re-assemble the upper cover on the
appliance (see service instructions
“6.4 Disassembling and assembling
housing parts”).
Check:
If the green LED on the top of the supply module is lit, it is working correctly
(module self test).
If the LED is not lit the supply module is defective and must be replaced
(module self test).
4 x