4. Programming
32 496478
To change: Key-in: Notes Default
Level A Exit Time 44
Y
1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Entry/Exit Volume 45
Y
0 No Entry/Exit tones from Loudspeaker
n EE tone volume from LS (1=low, 9=max) 5
CSID Code 50
Y
n....n Seed code for remote reset none
Set Time and Date 51
Y
..... see “Setting Time and Date”
Abort reset 53
Y
0 Abort System Y
1 Abort User
Level B final exit operation 60
Y
0 B=FE = FE (Final exit) Y
1 B=FE = NA (Normal alarm)
Level B Entry route 61
Y
0 B=ER = ER (Entry route) Y
1 B=ER = FE (Start entry timer)
Level B Exit Mode 62
Y
0 Low Tone Y
1 Instant set
2 Silent set
Level B Alarm response 63
Y
0 Keypad Sounder Only
1 Internal Sounder and keypad sounders Y
2 Local (all sounders, no comms)
3 Full alarm (all sounders and comms)
Level B Entry Time 64
Y
1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level B Exit Time 65
Y
1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds

Table of Contents