Use and maintenance manual – 10/2016 Rev. 3 Page 28
19.2 Warning codes
The machine alerts the operator of the warning codes by alternating the display of the warning code with the brief description (in
English) of the warning and remains in this status until the operator has pressed any key (except for [P7] ).
Table T19.2: Warning codes
description
display
Excessive wheel imbalance: it is
advisable to use the Optimisation
program.
19.3 Special visual signals
The machine gives special visual signals in certain cases. The special visual signals are listed in table T19.3.
Table T19.3: Special visual signals
Three decimal points lit
on one or both displays
Imbalance exceeds 999 grams. This signal can be triggered due to:
• Lack of machine calibration;
• Incorrect measures of the wheel dimensions;
• Incorrect setting of the Wheel Type;
• Incorrect setting of the Program Type.
Flashing green STBY LED The machine is in the STAND-BY mode. All LEDs and displays are switched off. To exit STAND-
BY mode, press any button (Except for [P7] ).
The left (or right) display
is flashing
A user action is being waited for.
The user’s action may be pressing a key to confirm or
continue the procedure in progress, or the selection
of a value or a menu option.
20. FIRE PREVENTION MEANS TO USE
CO
YES*: Can be used in the absence of more appropriate means or for small fires.
The information in the table above is general and can be used as a rough guide. The responsibility for the use
of each type of extinguisher must be obtained from the manufacturer.