Use and maintenance manual – 10/2016 Rev. 3 Page 27
19. SIGNALS
When abnormal operating conditions occur, the machine emits two types of signal:
• Error
• Warning
The Error signal is always accompanied by a triple beep indicating that the machine cannot run the command given by the operator,
or, during operation, conditions were encountered that prevent the action in progress from continuing.
The Warning signal is always accompanied by a double beep that prompts the operator to perform a particular action, or it refers to
the fact that the machine has changed status. In any case, the requested operation is not prevented or the current function is
completed.
19.1 Error codes
The machine indicates error conditions by alternating the display of an error code with a brief description (in English) of the error
cause.
The list of error codes and description outlines is provided in table T19.1. The machine displays the code for different times depending
on the error code itself, as indicated in the column "Error display" in table T19.1.
Table T19.1: Error codes
Error code Brief description Error display
(1)
Description Notes
Machine parameters internal error.
Contact technical support.
Rotation speed is too low.
stuck
TURNED OFF
Keypad blocked at start-up.
Release all keys, then turn off or restart the
machine. If the error
persists, contact
technical support.
CONFIRMATION
No communication processor
Turn the machine off and then on again. If
the error persists, contact technical
support.
The machine can still be used but all
functions related to the USB port are
CONFIRMATION
No communication with the eeprom
memory.
Turn the machine off and then on again. If
the error persists, contact technical
support.
CONFIRMATION
Lack of machine calibration data or
incorrect calibration data.
Carry out machine calibration for the
MOTO Wheel Type. If the error persists,
contact technical support.
Launch without weight or no pick-up A
signal in the Cal2 calibration phase.
Contact technical support.
Launch without weight or no pick-up B
signal in the Cal2 calibration phase.
Contact technical support.
CONFIRMATION
Hidden Weights program: the selected
point is too far from the external
The point must be included up to 120°
from the external imbalance position. See
CONFIRMATION
Hidden Weights program: the external
imbalance position is not included
between the W1 and W2 selected
Choose W1 and W2 points so that they
include the external imbalance position.
See chapter 16.
(1)
The error code can be exited in the following ways:
OPERATOR
CONFIRMATION
The machine exits the error code display when the operator presses any key (except for [P7] ).
OPERATOR ACTION
The machine exits the display of the error code when the operator takes an action related to the error
The machine displays the error code and its brief description once, then it returns to the previous status.
PERMANENT
The machine permanently displays this error code until its turn-off, therefore the error code cannot be