VIPER FROZEN MULTI FLAVOUR VALVE
INSTALLATION AND OPERATION MANUAL
Release Date: October 15, 2018
Publication Number: 919000012INS
Revision Date: October 16, 2019
Revision: B
Visit the Cornelius web site at www.cornelius.com for all your Literature needs.

Questions and Answers

  • S
    Scott SandersAug 9, 2025
    What to do if the Cornelius VIPER FMFV Control Unit valve is not dispensing the drink?
    • Y
      ydavisAug 9, 2025
      If the Cornelius Control Unit valve isn't dispensing drinks, there could be several reasons. First, ensure the compressed air pressure in the regulator is set to 45±5. Then, check the electrical connection to the MAC valve; if it's faulty, replace the defective MAC valve. Also, check the display cable connection. Finally, consider ice bridging or ice ball formation, which may require hammering (refer to the Operation section) or defrosting (refer to the Viper Product Manual).
  • M
    Michael HughesAug 25, 2025
    Why is there continuous valve leakage in my Cornelius VIPER FMFV Control Unit?
    • S
      Sierra VargasAug 25, 2025
      Continuous valve leakage in the Cornelius Control Unit can be due to a couple of issues. One potential cause is that the BIMBA cylinder is not closing or only partially closing, in which case you should replace the BIMBA cylinder. Another cause could be failure of the Diffuser assembly, requiring a service call to change the Diffuser or replace the O-ring.