MOBILTEX® DATA LTD.
Calgary, Alberta
www.corTalk.com
TITLE: RMU1 Installation and Configuration Guide
DOCUMENT NO.:
RMU1-MAN-001
SHEET:
38 of 53
REV:
1.14
Figure 39 RMU1CONFIG Main Screen
Next, attach the programming interface to the RMU1 that requires programming.
The first step in configuring a device is to read in the current settings from the unit. Click on “Read Config From
RMU1”. The “Link Status” field will briefly show “Busy” as the current configuration parameters are read from the
RMU1. After the link status returns to “Idle”, you will see the configuration settings currently in the RMU1. If the
RMU1 is not responding or not connected, an error dialog will pop up.
Once communications have been established with the RMU1, the RMU1 parameters can be configured for the
requirements of a particular installation site.
6.3.1 RMU1 Communications and Status
“RMU1 Communications and Status” is used for reading and programming the RMU1. It also displays some status
information.
6.3.1.1 Link Status
This field has three settings:
Disabled Serial port is not connected to the programmer
Idle Programmer is connected but there is no activity
Busy Programmer is trying to communicate with the RMU1
6.3.1.2 Firmware Version
This field contains the version number of the application code installed in the main processor of the RMU1.
6.3.1.3 Serial#
The manufacturing serial number of the RMU1 is indicated in this field.
6.3.1.4 Read Config From RMU1
This is used to get the current values configured in the RMU1. Note, if you have changed the values in any of the
configuration groups, the changes will be over written by pressing this button.