TITLE: RMU1 Installation and Configuration Guide
DOCUMENT NO.:
RMU1-MAN-001
SHEET:
41 of 53
REV:
1.14
Click the ‘Auto-Set Threshold’ button while the test station cap is not installed. Ensure that nothing is obscuring the
proximity sensor window on the RMU1. A new threshold value will be determined based on the current sense levels.
The new threshold will become active immediately after clicking the ‘OK’ button on the dialog. Pressing ‘Cancel’ will
revert to the prior threshold levels.
During normal operation, ensure that no wiring or any other objects are blocking the proximity sensor window from
being able to ‘see’ the test station cap when it is installed.
Figure 43 RMU1 Cap Proximity Sensor
6.3.1.11 Extract Datalogger Mem
The ‘Extract Datalogger Mem’ button allows readings stored in the internal memory to be extracted to a comma-
separated-value (CSV) file format that can be used with a spreadsheet application. This function requires the factory-
enabled datalogger option be present on the RMU1.
After clicking the button, the contents of the datalogger memory will be transferred from the RMU1. After the transfer
is completed, a prompt will appear for the target file name. The resulting file may be opened for analysis in various
applications that support the CSV format.
6.3.1.12 Clear Datalogger Mem
The ‘Clear Datalogger Mem’ button allows the RMU1 datalogger memory to be reset back to a blank state. This function
requires the factory-enabled datalogger option be present on the RMU1.
After clicking the button, a confirmation prompt will appear. If confirmation is given, then a progress display will be
shown as the RMU1 memory is erased.
6.3.1.13 Test Transmission
A test message can be sent to corView by clicking on the ‘Test Transmission’ button. The RMU limits the number of
test transmissions possible to six in a 12 hour period. Subsequent test transmission attempts will be ignored.
6.3.1.14 Reboot RMU1
Click the ‘Reboot RMU1’ button to restart the RMU1.
6.3.2 Measurement Type
Select the measurement type according to the installation application of the RMU1. Refer to section 5.2 for detailed
descriptions of each measurement type.