33
1
3
2
backwards
forward
SET
(selection / adjustment mode)
The system monitoring display consists of 3 blocks:
channeldisplay, tool bar and systemscreen (active
arrangement).
The channeldisplayconsists of two lines. The upper
line is an alpha-numeric 16-segment display (text dis-
play) for displaying channel names and menu items. In
the lower 7-segment display, the channel values and
the adjustment parameters are displayed.
Temperatures and temperature differences are indica-
ted in°C or K respectively.
2.2.1 Channeldisplay
channel display
2. Operation and function
2.1 Buttons for adjustment
The controller is operated via the 3 push buttons below
the display. The forward-button (1) is used for scrolling
forward through the display menu or to increase the
adjustment values. The backward-button (2) is similarly
used for scrolling backwards and reducing values.
In order to access the adjustment mode, scroll down
in the diplay menu and press the forward button (1) for
approx. 3 seconds after you have reached the last diplay
item. If an adjustment value is shown on the display,
the „SET“ icon is displayed. Now, you can access the
adjustment mode by using button 3.
• Press buttons 1 and 2 in order to select a channel
• Briey press button 3, „SET“ will ash
• Adjust the value by pressing buttons 1 and 2
• Briey press buttons 3, so that „SET“ permanently
appears, the adjusted value will be saved.
2.2 Systemmonitoringdisplay
!
Complete Monitoring-Display