36
CONVERT TO LP GAS (OPTIONAL)
This range is shipped from the factory set up to use natural gas. It can be
converted to operate on LP/propane gas by a qualified service technician.
The LP conversion kit is sold separately. The conversion to LP requires all
surface and oven burner gas orifices to be changed. In addition, the gas
pressure regulator must also be adjusted for LP.
See "Gas Conversion" section for detailed instructions.
To order LP conversion kit, see "Optional Parts" in the "Tools and Parts" section.
NOTE:
• All replaced orifices must be left with the consumer, including the
instructions and retrofit sizes and orifice indication.
COMPLETE GAS CONNECTION
1. Check that all range controls are in the OFF position.
2. Open the manual shut-off valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved noncorrosive leak-
detection solution. If bubbles appear, a leak is indicated. Correct any leak
found.