51
This range is factory-set for use with Natural gas (NG). The LP conversion kit is
sold separately. To order LP conversion kit, see "Optional Parts" in the "Tools
and Parts" section.
IMPORTANT: Gas conversions must be done by a qualified service technician
in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. The qualified agency
performing this work assumes the gas conversion responsibility.
CONVERT GAS PRESSURE REGULATOR
1. Turn manual gas shut-off valve to the closed position.
2. Unplug range or disconnect power.
3. Move the range out from the wall or installation space. Locate and
remove the regulator cover on the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
Regulator
cover