5-3-2-1. FUN 0: OVP setting
SETT <value>
Default
Model
150 ~ 165 @100=1V
16.5V <165>
SP series-112 / 212
300 ~ 330 @100=1V
33.0V <330>
SP series-124 / 224
600 ~ 640 @100=1V
64.0V <640>
SP series-148 / 248
Table 35. OVP setting
5-3-2-2. FUN 1 : OVP Recovery
SETT <value>
Default
Model
135 ~ 145 @100=1V
14.5V <145>
SP series-112 / 212
270 ~ 290 @100=1V
29.0V <290>
SP series-124 / 224
540 ~ 580 @100=1V
58.0V <580>
SP series-148 / 248
Table 36. OVP recovery
5-3-2-3. FUN 2 : UVP setting
SETT <value>
Default
Model
105 ~ 115 @100=1V
10.5V <105>
SP series-112 / 212
210 ~ 230 @100=1V
21.0V <210>
SP series-124 / 224
420 ~ 460 @100=1V
42.0V <420>
SP series-148 / 248
Table 37. UVP setting
5-3-2-4. UVP Recovery
SETT <value>
Default
Model
125 ~ 135 @100=1V
12.5V <125>
SP series-112 / 212
250 ~ 270 @100=1V
25.0V <250>
SP series-124 / 224
500 ~ 540 @100=1V
50.0V <500>
SP series-148 / 248
Table 38. UVP recovery
5-3-2-5. FUN 4 : UV Alarm
SETT <value>
Default
Model
105 ~ 115 @100=1V
10.5V <115>
SP series-112 / 212
210 ~ 230 @100=1V
21.0V <210>
SP series-124 / 224
420 ~ 460 @100=1V
42.0V <420>
SP series-148 / 248
Table 39. UV alarm