File No: 1.9.01.00018 Version No:A
Note: Subsequent update versions of this manual will not be noticed.thank you.
16 / 24
After 30 s, the is completed;
Entering the automatic rinsing stage, first cleaning for 3 minutes, then draining for 30s, after the rinsing process
rec recirculation for 5 times, the whole cleaning process is over, and the screen shows "OFF" , in to stand by
state, the whole process takes about 37 minutes.
6.Remove water pipe fixed support, water pipe, water retaining plate, take out water pump, floatball, ice shovel
(removal mode refer to parts removal / installation process ).
Mix with 8 liters of warm water (45~50℃) and 4 packs of cleaning agents (KAY DELIMER, 56.7g/ packs) to
form a cleaning solution (the amount of cleaning fluid needs to be properly adjusted for the amount of
cleaning parts).
8. Soak the parts in the cleaning solution for more than 5 minutes (it is recommended to soak for .
Wear rubber gloves after soaking and clean parts carefully with soft nylon brush, sponge or soft cloth.
7.
5.
Scrub the ice shield and inner wall
of the ice sheet
3
4