Leveling and Adjustment
Screwing home four adjustable parts of the legs first, and then screwing the legs into the ice maker
bottom plate
Moving the ice maker to the installation place, and adjusting the legs to ensure the ice maker is
leveling.
Water Supply/Purge
7.1 Water Supply
With local potable water quality, determining if a water treatment system is needed to prevent
sediment formation, filter out impurities and remove bleach smell
Please install the water supply pipe according to the below instruction
Do not connect the ice maker to the hot water pipe
The water supply pressure range is 1 bar 5 bar. Using a water pressure regulator for water
supply pressure over rang
Individual water faucet must be installed for the ice maker.
7.2 Purge
When installing the drain hose, follow these guidelines to be sure all purged water flowing into the
gully drain
The main gully drain capacity shall be enough for all drain water
The drain hose should be wrapped with insulation material to prevent condensation
The drain hose of the water-cool condenser and the drain hose of the ice bin should be placed
separately
Bout 2.5 centimeters drop is needed for each one meter additional drain hose and must not be
bent.
Good
Bad
Bad
Good
Bad
Bad
7.