22 / 24
Disassembly of water retaining platesBoth hands hold the rotating shaft at the same end of the
baffle, and pull the side of the baffle out of the pin hole by pulling it to the other end.
16. Regular Cleaning
Note
If water is left in the machine in an environment below 0°C, it may cause
serious damage to the machine parts. This fault is not covered by warranty.
Clean environment: clean the area around the ice maker regularly to keep the environment clean to
support ice maker running efficiently.
Shell cleaning: Use sponge or soft cloth with neutral cleaning agent to clean, and wipe it up with a clea
n
soft cloth. Stainless steel cleaner can be used when necessary.
Air filter clean: filter can arrest dirt or dust in the air enter condenser. It can postpone condenser fro
m
blocking. If the filter is blocked, the ice production will decrease. We recommended to clean the air filte
r
once or twice a month
Remove the air filter
Please clean the air filter with a vacuum cleaner or a soft brush. If the air filter is severely clogged
,
clean it with warm water and a neutral cleaner
Put it back after the filter is completely dry
17. Condenser Cleaning
It is recommended to clean the
condenser every six months by following steps:
Use a soft brush or vacuum cleaner to clean the outside of the condenser, the act direction should
be from top to bottom ( it will break condenser fins act from one side to another;
Use commercial coil (air conditioning) cleaner. Follow the instructions and precautions for coil
cleaning agent when using. The damaged fins should be straightened with a fin comb.