EasyManuals Logo

Coway CHP-06DL Service Manual

Coway CHP-06DL
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
Parts location diagrams
7-6
Coway co., Ltd
1 CN1: YW396-03V (White)
AC IN
Pin No. Signal
1
AC Source
2
AC Source
2 CN2: YW396-03V (RED)
HEATER
Pin No. Signal
1 Relay
2 AC Source
3 CN3: YW396-03V (BLUE)
COMP
Pin No. Signal
1
AC Source
2
Relay
4 CN4: SMW420-06
3-WA
Y
Pin No. Signal
1 3. 5 DC 24V
2 COLD VAL
VE
4 ROOM VAL
VE
6 HOT V
ALVE
5 CN5: SMW420-04
FEED&NOS
Pin No. Signal
1 3 DC 24V
2 FEED VAL
VE
4 NOS VAL
VE
6 CN7: SMW250-10
3-WA
Y
Pin No. Signal
1 DC 5V
2 SIGNAL
3 SIGNAL
4 SIGNAL
5 SIGNAL
6 SIGNAL
7 SIGNAL
8 SIGNAL
9 SIGNAL
10 GND
7 CN6: SMW250-06
FRONT
Pin No. Signal
1 SIGNAL
2 SIGNAL
3 SIGNAL
4 SIGNAL
5 SIGNAL
6 SIGNAL
8 CN8: SMW420-02
F
AN
Pin No. Signal
1 TR
2 DC 24V
9 CN9: YW025-02
Overflow
Pin No. Signal
1 GND
2
SIGNAL
0 CN11: YMW025-03
REED LEVEL
Pin No. Signal
1
SIGNAL
2
SIGNAL
3 GND
! CN10: SMW250-03(RED)
HOT THERMISTOR
Pin No. Signal
1
Signal
2 NC
3
DC 5V
@ CN12: SMW250-02(BLUE)
COOL
THERMISTOR
Pin No. Signal
1
SIGNAL
2
GND
CHP-06DL-eng.indb 6 2007-10-22 ソタタ・9:13:32

Other manuals for Coway CHP-06DL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coway CHP-06DL and is the answer not in the manual?

Coway CHP-06DL Specifications

General IconGeneral
BrandCoway
ModelCHP-06DL
CategoryWater Filtration Systems
LanguageEnglish