Crestron SIMPL+
®
Software
Language Reference Guide - DOC. 5797G SIMPL+
®
z 147
Example:
(Refer to "File Functions Overview"on page 116)
SIGNED_INTEGER nFileHandle;
STRING sBuf [ 4096 ];
StartFileOperations();
sBuf = “Hello World!”;
nFileHandle = FileOpen ( “MyFile”, _O_WRONLY );
IF (nFileHandle >= 0)
{
if( FileWrite(nFileHandle, sBuf, 4096) > 0 )
PRINT ( “Written to file: %s\n”, sBuf );
IF ( FileClose ( nFileHandle ) <> 0 )
PRINT ( “Error closing file\n” );
}
EndFileOperations();