344 z SIMPL+
®
Language Reference Guide - DOC. 5797G
Version:
SIMPL+ Version 2.00 only. This function is not available in Versions 1.00 or 3.00.
Control System:
X-Generation only
SetCresnet
Name:
SetCresnet
Syntax:
SetCresnet(INTEGER CRESNET_ID, INTEGER JOIN_NUMBER,
INTEGER TYPE);
Description:
Sets the state of the join number on a particular Cresnet Network ID. Note that the
device must be defined in SIMPL Windows and the join number to use must have a
signal tied to it for this function to work.
Parameters:
CRESNET_ID is an INTEGER containing the ID of the Cresnet Network device to
set the join number. JOIN_NUMBER is an INTEGER containing the Join number to
set. TYPE is one of several predefined constants:
din: Digital inputs from device (symbol output list)
ain: Analog inputs from device (symbol output list)
dout: Digital outputs to device (symbol input list)
aout: Analog outputs to device (symbol input list)
Return Value:
None.
Example:
Assuming a touchpanel has been defined at Cresnet ID 07, and press 42 and feedback
69 have signal names tied to them, this SIMPL+ statement will connect the two:
SetCresnet(0x07,69,dout) = GetCresnet(0x07,42,din);
Version:
SIMPL+ Version 2.00 only. This function is not available in Versions 1.00 or 3.00.
NOTE: This is not a permanent connection; it will only set the state when this
statement is executed.