Crestron SIMPL+
®
Software
Language Reference Guide - DOC. 5797G SIMPL+
®
z 345
Control System:
X-Generation only
SetSlot
Name:
SetSlot
Syntax:
SetSlot(INTEGER SLOT_NUMBER, INTEGER JOIN_NUMBER,
INTEGER TYPE);
Description:
Sets the state of the join number on a particular card slot. Note that the device must
be defined in SIMPL Windows and the join number to use must have a signal tied to
it for this function to work.
Parameters:
SLOT_NUMBER is an INTEGER containing the slot number of card to set the join
number. JOIN_NUMBER is an INTEGER containing the Join number to set. TYPE
is one of several predefined constants:
din: Digital inputs from device (symbol output list)
ain: Analog inputs from device (symbol output list)
dout: Digital outputs to device (symbol input list)
aout: Analog outputs to device (symbol input list)
Return Value:
None.
Example:
Assuming a relay card has been defined in Slot 1 and Relay A2 has a signal name tied
to it, and a touchpanel has been defined at Cresnet ID 07, and press 42 has a signal
name tied to it, this SIMPL+ statement will connect the two:
SetSlot(1,2,dout) = GetCresnet(0x07,42,din);
Version:
SIMPL+ Version 2.00 only. This function is not available in Versions 1.00 or 3.00.
Control System:
X-Generation only
NOTE: This is not a permanent connection; it will only set the state when this
statement is executed.