EasyManua.ls Logo

Crestron SIMPL+ - Compiler Error 1401: Variable Cannot Be Used for Assignment; Compiler Error 1402: Variable Can Only Be Used for Assignment

Crestron SIMPL+
374 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Software Crestron SIMPL+
®
318 z SIMPL+
®
Language Reference Guide - DOC. 5797G
Compiler Error 1401
assignment error: Variable cannot be used for assignment:
'<identifier>'
Function arguments that have been declared as ReadOnlyByRef can only have their
values read; values cannot be assigned to them.
The following are examples of this error:
FUNCTION MyFunc( INTEGER x, ReadOnlyByRef INTEGER y )
{
x = 5; // ok
x = y; // ok – the value of y can be read
y = 6; // error – y is read-only
}
Compiler Error 1402
assignment error: Variable can only be used for assignment:
'<identifier>'
STRING_OUTPUT variables can only have their values read. Once assigned a
value, that value is immediately acted upon by the control system, and the value is
assumed to be unknown thereafter.
The following are examples of this error:
STRING_OUTPUT sOut;
STRING str[100];
FUNCTION MyFunc()
{
str = “abc”; // ok
sOut = str; // ok – sOut can be assigned a value
sOut = “abc”; // ok – sOut can be assigned a value
str = sOut; // error – the value of sOut is lost
Print( “str = %s”, str ); // ok – STRINGs can be read and
written
Print( “sOut = %s”, sOut ); // error – the value of sOut is
unknown
}